quick selector ngc – sound rated systemsUL Product SpecTM also allows you to easily access designs when the design number is known. From the homepage, select Products, Systems or Assemblies > Building or Fire Systems > Fire Rated Walls, Floors, Beams and Columns > Search by Assembly Number. Enter the design number and click on Search. As can be seen, locating fire-resistance …are UL Classified for fire resistance and can be used in any UL Design in which Type ULTRACODE panels are listed. On the face, along the long edge of each panel, the UL Type Designation is printed for easy identification by building inspectors. • Commercial or residential applications where 3/4 in. (19.1 mm) Type X panels are requiredKnurled surface reduces screw sidespin. Cross tee punchings easily accommodate type F light fixtures. Meets or exceeds ASTM C645. UL listed in 36 fire rated designs, many with light fixtures and duct openings. Reduces field cutting in rooms that are multiples of 3' wide. (widths of 12', 15', 18', etc) Corridors. Offices. According to section II, Subsection 9 of the BXUV Guide Information, Gypsum board thicknesses specified in specific UL designs are the minimums.Additional layers of gypsum or greater thicknesses of gypsum board are permitted in any UL design, provided the fastener length is increased to provide penetration into framing that is equal to or greater than that achieved with the specified gypsum ...

Fire Rating. 1 hours. System STC. 39. System Thickness. 4.625 in. CAD/Revit & Acoustics. Revit PDF. Visit UL U415 UL System A on the UL website. Return to results :: Keyword: "I504" Wallboard. UL Certified. DOCUMENT: CKNXC.R2717 · Product Code (UL CCN): CKNXC The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description). See below for more info on …See when UL Solutions received your product samples, when they are returned, picked up, destroyed or archived. Documents. Search, View, and download your UL Solutions reports, procedures and global certifications. Browse documents and associated supplements. Download multiple documents at once.

Title: FIRE-RESISTANCE RATINGS - ANSI/UL 263 | UL Product iQ Author: ctallen Created Date: 5/7/2019 4:29:04 PM

Mid-Am BuildingFor 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Com Ul design k504 and k506 Keyword Found Websites Listing Keyword-suggest-tool. No technical changes have been made. It is a key differentiator for products within the exterior wall assembly market.myUL® Client Portal. myUL® is a secure source that gives you an enhanced level of access into your UL Solutions project files, such as product information, documents and services. Having easy access to this in-depth information empowers you to make decisions that will positively impact your bottom line. By providing you with better visibility ...Overview. Sheetrock® Brand Firecode® X Panels (UL Type SCX) are 5/8 in. (15.9 mm) Type X gypsum panels that feature a noncombustible gypsum core that is encased in 100% recycled face and back papers that form a high strength composite design. The face paper is folded around the long edges to reinforce and protect the core, and the ends are ...

You have many options when it comes to designing your business website, take a look at these restaurant website design examples to get some ideas. * Required Field Your Name: * You...

Looka Logo Maker combines your logo design preferences with Artificial Intelligence to help you create a custom logo you'll love. All it takes is a few clicks and five minutes. Let's make a logo! 01. Our logo maker is easy. Start by entering your company name and industry, then select the perfect logo styles, colors, and symbols that you like ...

Floor-Ceiling Assemblies. Here, you can find drawings for our UL fire-rated floor assemblies and UL fire-rated ceiling assemblies. Our range of drawings can help pros plan projects …Mid-Am BuildingGCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6We would like to show you a description here but the site won’t allow us.It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.We would like to show you a description here but the site won’t allow us.

Roof-Ceiling Assemblies. Helpful documents and resources for USG’s roof assemblies can be found on this page. Refer to our roof-ceiling assembly documents, which includes UL fire-rated roof assemblies, for easy guidance through …the UL design numbers and ceiling sys-tem products that correspond to the fire-rated assemblies that meet your needs. 4. Refer to the Fire Resistance Selector on page 19 for a list of Fire Guard fire resis-tive ceilings. 5. Review performance data for specific Fire Guard ceilings and suspension systems throughout this catalog that meet yourFor 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. UL Outline UL 504 Edition 1 UL LLC Outline of Investigation for Mineral-Insulated Metal-Sheathed Cable Edition Date. UL Design K504 and K506 per details on page 24. No technical changes have been made.BXUV.U415 ­ Fire Resistance Ratings ­ ANSI/UL 263. System I, butt joints in liner panels are staggered min 36 in. Butt joints backed with 6 in. by 22 in. strips of 3/4 in. thick gypsum wallboard (Item 4). Wallboard strips centered over butt joints and secured to liner panels with six 1­1/2 in. long Type G steel screws, three screws along the ... 1 layer 3/4" Thick, USG Structural Panel Concrete Subfloor (USGSP), with long edges tongue and grooved, long dimension of panels to be perpendicular to Joists (UL Type USGSP) Structo-Crete® Brand Structural Panels.

UL Design U411, a generic steel stud, gypsum panel assembly, is an example of what is in the directory. At the beginning of that listing, as well as all others, is a note that states, “See general information for Fire-resistance Ratings.” ... For example, UL U411 calls for a minimum 2 1/2 inch, 18 mil stud spaced 24 inches on center. The ...

Welcome to our resource library. Here you’ll find business intelligence-building tools such as case studies, technical reports, checklists, fact sheets, user guides, webinars, FAQs and more. You can filter by industry and type of resource to …It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.Jul 9, 2021 · To find these designs, follow this step-by-step process: On Product iQ, scroll down to the section entitled “IQ PLUS SEARCH TOOLS” and click on “Building Materials, Systems and Installation Codes,” then click on “Fire Rated Roofs, Walls, Floors, Beams and Columns.”. In the menus on the left, select or type the following: Keyword ... calculated design load. The committee reasoned that had the cross-sectional area of the columns been slightly greater, the test would have lasted at least 3 hours. After careful study, UL engineers agreed with this assessment, specifically certifying that UL V304 with 5-ply (instead of 4-ply) columns could be approved as a 3-hr fire wall.This new assembly, known as UL W404 contains several prominent attributes and increases the total number of fire resistive assemblies sponsored by MBMA to 13. UL W404 preserves the most common and efficient metal building system construction practices of the industry in this new 1-hr non-loadbearing exterior wall system.UL Fire Resistance Designs that are listed for conformity with Canadian requirements, and thereby bearing the cUL Mark, are identified as such in our Directories in two ways. First, the UL/ULC both use Category Code Numbers (CCNs) to identify product categories. Each category code in itself will provide full information for the Designs for that ...Roof-Ceiling Assemblies. Helpful documents and resources for USG’s roof assemblies can be found on this page. Refer to our roof-ceiling assembly documents, which includes UL fire-rated roof assemblies, for easy guidance through …

UL Type Designations; Material Estimators Material Estimators. Sheetrock® Wallboard Estimator; Ceilings Materials Estimator; ... All Design Studio & Project Tools. Inspiration. Project Gallery Project Gallery. Brock Commons, University of British Columbia Case Study; The Bow Tower;

UL Category Control No. UL File No. UL Category Control No. Description UL 508A Paragraph(1) Representative Photo Bulletin Number Description Web link UL 508 NKJH E205542 Combination Motor Controller 30.1.5 31.1.4 33.1.1 34.1.1 140M • Self-protected combination motor controllers • Provide disconnect, overcurrent protection, …

You could get cheap designer clothing by taking advantage of sample clothes sales online. And then, you can build a high-quality wardrobe with clothes that not only make a lasting ...Compliance solutions for buildings, products, systems, and designs to meet fire regulations. Fire-rated wall, floor and ceiling assemblies provide the necessary fire and smoke …If you have any questions, please reach out to our customer service team at 1-800-879-8000 (US) or 1-800-363-4458 (Canada) for assistance. Fire Protection Design Team. Hilti North America. 3701 W. Royal Lane, Suite 100, Irving, TX 75063. P 1-800-879-8000 I …We would like to show you a description here but the site won’t allow us.Meets a broad range of UL design assemblies: D501, D502, G523, G524, G526, G527, G528, G529, I504, I512, I518, J502, L502, L508, L513, L515, L525, L526, L529, L564, …three layers 5/8" thick gypsum board (ul type ulix™) assembly options: ul design no. i506 b notes: for the most up-to-date information or assembly options, refer to the ul fire …For 1-hour assemblies National Gypsum developed UL design I504 which is a 1-hour horizontal assembly that consists of 3-58 steel studs 16 oc. Com Ul design k504 and k506 Keyword Found Websites Listing Keyword-suggest-tool. No technical changes have been made. It is a key differentiator for products within the exterior wall assembly market.Search the world's information, including webpages, images, videos and more. Google has many special features to help you find exactly what you're looking for.can you use pulp riot blank canvas on wet hair. kalamazoo police shooting; did bridges of madison county win any awards; fire in oxford ma today

See when UL Solutions received your product samples, when they are returned, picked up, destroyed or archived. Documents. Search, View, and download your UL Solutions reports, procedures and global certifications. Browse documents and associated supplements. Download multiple documents at once.Artists can render a 3D design from a 2D one with a 3D modeling program. After producing a 2D design, an artist will use the 3D modeling program's tools to project the design into ... Roof-Ceiling Assemblies. Helpful documents and resources for USG’s roof assemblies can be found on this page. Refer to our roof-ceiling assembly documents, which includes UL fire-rated roof assemblies, for easy guidance through the assembly of a roof or ceiling on your next project. One-Hour Wall Membrane (Based on UL Design U 301) The membrane consists of two layers of 5/8” (15.9 mm) type X gypsum board directly applied to framing or furring. The base layer of gypsum board is applied either parallel or at right angles to wall or partition framing 16” (406 mm) o.c. and attached with 1” (25 mm) Type S or S-12 drywall ...Instagram:https://instagram. slope roblox unblockedhoof funeral home reedsburg wi obituariesarcane odyssey dark seashiftsense schedule CGC Ceiling Systems - Version One. The UL assembilies listed below are Cretified for use in Canada by UL and comply with CAN/ULC S101 for fire resistence. The Standards Council of Canada recognizes UL as an accredited testing and cerification organization for certification of materials and systems to Canadian standards. You have been logged out. You have been logged out due to inactivity what time are the thunderstorms tomorrowdiamond43 onlyfans If you have any questions, please reach out to our customer service team at 1-800-879-8000 (US) or 1-800-363-4458 (Canada) for assistance. Fire Protection Design Team. Hilti North America. 3701 W. Royal Lane, Suite 100, Irving, TX 75063. P 1-800-879-8000 I F 918-254-1679. texas tech university webraider More designs added to the fire and sound selector, including: a 1-hour ceiling membrane (UL Design I504), a 3-hour area separation wall (UL Design W454) and a 1-hour rated floor-ceiling assembly using SoundBreak ® XP ® (UL Design M514). A new section identifying the UL-Core designation of all NGC gypsum board products.We would like to show you a description here but the site won’t allow us.